The GIB series: Air-cooled medium pressure booster compressors for the compression of air, nitrogen, helium and argon – for continuous operation in industrial applications
BAUER 25 – 90 bar, air & nitrogen, helium & argon, 2200 – 5750 l/min (GIB-series)
Opis
Type
designation |
Effective
free air delivery ¹ |
Intake
pressure |
Shut-down pressure
min. | max. ² |
No. of
compr. stages |
Speed
approx. |
Motor
output |
Power
consumption ¹ |
Net weight approx. | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
l/min | m³/h | cfm | barg | bar | bar | rpm | kW | kW | kg | lbs | ||
GIB 23.7-37 | 2200 | 132 | 77 | 4 | 25 | 40 | 2 | 1140 | 37 | 15 | 1160 | 2560 |
3070 | 184 | 108 | 6 | 35 | 60 | 22 | ||||||
3950 | 237 | 139 | 8 | 40 | 80 | 29 | ||||||
4850 | 291 | 171 | 10 | 50 | 80 | 31 | ||||||
5750 | 345 | 203 | 12 | 50 | 80 | 34 |
1 Free air delivery according to ISO 1217, power consumption at maximum final pressure under certain conditions. Other ambient conditions result in different performance data. Direct-coupled units: Values valid for 50 Hz.
</div>
</div>
2 Shut-down pressure (sensor setting).
3 Suitable for helium under certain conditions. Please check with BAUER. Certain restrictions must be considered with regard to input and final pressure.
4 Max. safety valve pressure setting = max. operating pressure. Reduced switch-off pressure.
CORRECTION FACTOR FOR FREE AIR DELIVERY
Helium free air delivery = air free air delivery × 0.8
CORRECTION FACTOR FOR POWER CONSUMPTION
Helium power consumption = air power consumption × 1.06