Steo Sp. z o.o. Kompresory Wysokociśnieniowe Środki Pianotwórcze

AERO-GUARD

AERO-GUARD

Long filter service lives

Cost-effective operation

Flow rate 100 – 1000 l/min (AERO-GUARD) and 260-450 l/min (AERO-GUARD-OX)


AERO-GUARD CO2 absorber
AERO-GUARD CO2 absorber

Opis

Long filter service lives

Cost-effective operation

Flow rate 100 – 1000 l/min (AERO-GUARD) and 260-450 l/min (AERO-GUARD-OX)

The constantly increasing levels of CO2 concentration in the air resulting from unfavourable environmental influences are making it more and more difficult for the operators of filling stations to be sure of achieving compliance with legally binding maximum limits for CO2. With AERO-GUARD you are always on the safe side!

Dane techniczne

AERO-GUARD
Designation/Size Suitable for
free air delivery rates ¹
Dimensions
(W × D × H)
Operating weight ²
  l/min cm kg
Aero-Guard-S 100 – 150 50 × 46 × 72 26
Aero-Guard-M 160 – 230
Aero-Guard-L 240 – 320
Aero-Guard-XL 330 – 450
Aero-Guard-XXL 460 – 680
Aero-Guard-Duo 1000 650 – 1000 85 × 62.5 × 87 54
AERO-GUARD-OX
Designation/Size Suitable for
free air delivery rates ¹
Dimensions
(W × D × H)
Operating weight ²
  l/min cm kg
Aero-Guard-OX-L 260 – 320 50 × 46 × 72 26
Aero-Guard-OX-XL 330 – 450 50 × 46 × 72 26

¹ Free air delivery of the connected compressor measured with cylinder filling from 0 – 200 bar ± 5%
² Includes filter cartridge and 10-litre water ballast

Technical operating data
  AERO-GUARD: AERO-GUARD-OX:
CO2 input concentration: max. 1000 ppmv CO2 max. 2000 ppmv CO2
CO2 output concentration: 1/3 of the input concentration = max. 330 ppmv CO2 at 1000 ppmv input concentration CO2 1/5 of the input concentration = max. 400 ppmv CO2 at 2000 ppmv input concentration CO2
Rel. moisture of the intake air: 10 to 100% 10 to 60%
Ambient temperature: +5 to +45°C +5 to +45°C
Temperature of the intake air: +5 to +45°C +5 to +45°C
Air flow rate: 100 – 1000 l/min 260 – 450 l/min
Service life: 50 unit operating hours
(at free air delivery rate of 680 l/min and 1000 ppmv input concentration CO2)
or 1 year if the unit does not reach this number of operating hours
37 system operating hours
(at free air delivery rate of 450 l/min and 1000 ppmv input concentration CO2)
or 1 year if the system does not reach this number of operating hours

AERO-GUARD / AERO-GUARD-OX scope of delivery

  • Intake pipe (compatible connecting hoses must be ordered separately; see "Options")
  • Water barrel, 60 l (for AERO-GUARD DUO – 2 × water barrel, 60 l)
  • Filter cartridge; filling: 9 kg special carbon dioxide absorber

Wideo