Steo Sp. z o.o. Kompresory Wysokociśnieniowe Środki Pianotwórcze

AEROTEST SIMULTAN

AEROTEST to measure the cleanliness of breathing air


AEROTEST
Impactor
Cylinder with tubes
AEROTEST
Impactor
Cylinder with tubes

Opis

Increasing damage to the environment and enforced regulations for breathing air quality such as DIN EN 12021 mean that the requirements to be met by the operators of filling stations are getting stricter all the time.

With the AEROTEST SIMULTAN HP portable breathing air tester to measure cleanliness, you will always be on the safe side!

Tester tubes simultaneously and accurately measure compliance with the concentration limit for CO, CO2 and water vapour in the compressed air. An "impactor" is used for simultaneous verification of mineral and synthetic oil content in the breathing air.

The breathing air tester has been to all but exclude the risk of incorrect measurements as a result of operator error. The device does not have to be calibrated either.

A pressure reducer and special nozzles keep volume flow constant at all times, thereby safeguarding consistently accurate measurements. The AEROTEST SIMULTAN HP breathing air tester checks for compliance with the limit values specified in standard DIN EN 12021¹ for breathing air¹, thereby providing effective protection for life, health and equipment.

¹ Check for concentration of CO, CO2, water vapour and residual oil. Oxygen content is not measured.

Dane techniczne

AEROTEST HP
Carrier case Length × width × height (mm): 350 × 300 × 85
Colour: Black
Weight with contents: approx. 3 kg
Pressure reducer Input: male thread G5/8-300 bar (connection by hand)
Max. intake pressure: 300 bar
Pressure gauge: 0 to 400 bar
Output: 9 mm plug-in connector for measuring instrument
Overpressure valve: set to 10 +2 bar
Adapter 1 Input: female thread G5/8-200 bar
Output: female thread G5/8-300 bar for pressure reducer
Adapter 2 Input: female thread G5/8-200 bar
Output: female thread G5/8-300 bar for pressure reducer
Measuring instrument Length × width (mm): 100 × 38
Height including Dräger tube mount (mm): 230
Connection for compressed air supply   9 mm nipple
Intake pressure Set on delivery: 8.5 bar
Volume flow CO and CO2 tubes: 0.2 l/min
Impactor and H2O tubes: 4 l/min
Tubes for nitrous gases:  
AEROTEST ALPHA
Carrier case Length × width × height (mm): 350 × 300 × 85
Colour: Black
Weight with contents: approx. 3 kg
Pressure reducer Input: Nipple
Max. intake pressure: 15 bar
Pressure gauge: 0.3 to 15 bar
Output: 9 mm plug-in connector for measuring instrument
Overpressure valve: none
Adapter 1 Input: 9 mm coupling
Output: Male thread G 1/4
Adapter 2 Input: Female thread G 1/4
Output: 12 mm nipple
Measuring instrument Length × width (mm): 100 × 38
Height including Dräger tube mount (mm): 230
Connection for compressed air supply   9 mm nipple
Intake pressure Set on delivery: 3.0 bar
Volume flow CO and CO2 tubes: 0.2 l/min
Impactor and H2O tubes: 4 l/min

Wideo